| Features: HEW-1800HSW
series |
| Human body measuring |
8 CCD cameras capture the body with less dead
angles. |
| Wide and accurate |
Each CCD camera measures the close-up of the
shape within the limited area. The montage of all images from
each camera makes up the complete figure. |
| Intensity Data |
Intensity data can be acquired as well as shape
data. By this intensity data, it is able to see markers sealed
on the subject, which will be used to measure the subject’s
size and analyze the data. |
| Safe laser |
The laser slit light is guaranteed its safety
by clearing JIS safety standard (class 2). |
| Options |
Versatile customization and options:Color-version
of illuminance image And more… |
|
|
|
|
|
|
|
|
| HEW-1800HSW [Human
body measuring type; High standard] |
| Position of Datum Plane |
650mm (ahead from detective
head) |
| Measurable Area |
1,800mmx750mm |
| Measurable Depth |
600mm |
| Accuracy* |
0.8mm |
| Measuring Time |
10~60sec/all round (variable) |
| Output Data |
Shape and Intensity data |
| Number of Output Data |
552,960(1152x480) |
| Laser Slit Light Source |
Semiconductor laser Wavelength
635mm and 690mm |
| Laser Scanning |
Stepping Motor |
| Size of Detective Head |
4,000mm(W)x2,000mm(D)x2,100mm(H) |
|
|
|
|
*Least Mean Squared
|
|

|
|
|
|
|
|
|
|
|
 |
|
|
|